ECONOMY – SAFETY – EFFICIENCY

iLEC MCT – Epoxy Casting Current Transformer

Epoxy Casting Current Transformer

Model MCT Round-Type

1. Introduction

  • Epoxy Cast Current Transformers are devices used to convert large currents to standard small values (1A or 5A) for metering and protection purposes in electrical systems.
  • iLEC MCT is a metering current transformer used for ammeters, energy meters, and monitoring devices.
  • It features high accuracy (Class 1) and operates stably under normal load conditions.

2. Features

  • Solid epoxy cast, excellent insulation, moisture-proof, and dust-proof.
  • High durability, safe operation.
  • Compact size, easy to install in electrical cabinets.
  • Stable accuracy, long service life.
  • Suitable for low-voltage and medium-voltage electrical systems.

3. General Specifications

Parameter Values
Type Metering current transformer
Primary current range 5A to 6000A
Secondary current (In) 1A or 5A
Accuracy CL 0.5, CL1, CL3
Burden From 5VA to 30VA
Nominal voltage (Un) Max. 660V
Nominal Frequency (fn) 50/60Hz
Basic Insulation 660V
Insulation strength 3kV / 1min
Ambient temperature -20ºC ~ 50ºC
Continuous current 1.2 x In

4. Ordering Code

iLEC Epoxy CT ordering code

■ Square type

iLEC square type MCT

■ Round type

iLEC round type MCT

■ MCT R0 Series
● Dimension
Model Width Height Thickness Outside Ø
MCT-R0 98 120 40 Ø98
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R0 MCT-R0 - 5/5A - CL.1 - 5VA 5/5A 5VA
MCT-R0 - 10/5A - CL.1 - 5VA 10/5A
MCT-R0 - 15/5A - CL.1 - 5VA 15/5A
MCT-R0 - 20/5A - CL.1 - 5VA 20/5A
MCT-R0 - 30/5A - CL.1 - 5VA 30/5A
MCT-R0 - 40/5A - CL.1 - 5VA 40/5A
MCT-R0 - 50/5A - CL.1 - 5VA 50/5A
MCT-R0 drawing dimensions

■ MCT R25 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R25 93 100 50 Ø25 Ø78
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R25 MCT-R25 - 50/5A - CL.1 - 5VA 50/5A 5VA
MCT-R25 - 75/5A - CL.1 - 5VA 75/5A
MCT-R25 - 100/5A - CL.1 - 5VA 100/5A
MCT-R25 drawing dimensions

■ MCT R30 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R30 93 100 50 Ø30 Ø78
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R30 MCT-R30 - 150/5A - CL.1 - 5VA 150/5A 5VA
MCT-R30 - 200/5A - CL.1 - 5VA 200/5A
MCT-R30 - 250/5A - CL.1 - 5VA 250/5A
MCT-R30 - 300/5A - CL.1 - 5VA 300/5A
MCT-R30 drawing dimensions

■ MCT R40 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R40 98 120 35 / 45 Ø40 Ø98
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R40 MCT-R40 - 250/5A - CL.1 - 5VA 250/5A 5VA
MCT-R40 - 300/5A - CL.1 - 5VA 300/5A
MCT-R40 - 400/5A - CL.1 - 5VA 400/5A
MCT-R40 - 500/5A - CL.1 - 5VA 500/5A
MCT-R40 drawing dimensions

■ MCT R60 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R60 109 139 35 Ø60 Ø109
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R60 MCT-R60 - 400/5A - CL.1 - 5VA 400/5A 5VA
MCT-R60 - 500/5A - CL.1 - 5VA 500/5A
MCT-R60 - 600/5A - CL.1 - 5VA 600/5A
MCT-R40 - 500/5A - CL.1 - 5VA 500/5A
MCT-R40 drawing dimensions

■ MCT R85 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R85 141 166 35 Ø85 Ø141
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R85 MCT-R85 - 800/5A - CL.1 - 5VA 800/5A 5VA
MCT-R85 - 1000/5A - CL.1 - 5VA 1000/5A
MCT-R85 - 1200/5A - CL.1 - 5VA 1200/5A
MCT-R85 - 1500/5A - CL.1 - 5VA 1500/5A
MCT-R85 - 1600/5A - CL.1 - 5VA 1600/5A
MCT-R85 - 2000/5A - CL.1 - 5VA 2000/5A
MCT-R85 - 2500/5A - CL.1 - 5VA 2500/5A
MCT-R85 drawing dimensions

■ MCT R125 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R125 185 213 35 Ø125 Ø185
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R125 MCT-R125 - 2000/5A - CL.1 - 5VA 2000/5A 5VA
MCT-R125 - 2500/5A - CL.1 - 5VA 2500/5A
MCT-R125 - 3000/5A - CL.1 - 5VA 3000/5A
MCT-R125 - 3200/5A - CL.1 - 5VA 3200/5A
MCT-R125 - 4000/5A - CL.1 - 5VA 4000/5A
MCT-R125 drawing dimensions

■ MCT R150 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R150 210 242 35 Ø150 Ø210
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R150 MCT-R150 - 3000/5A - CL.1 - 5VA 3000/5A 5VA
MCT-R150 - 3200/5A - CL.1 - 5VA 3200/5A
MCT-R150 - 4000/5A - CL.1 - 5VA 4000/5A
MCT-R150 - 5000/5A - CL.1 - 5VA 5000/5A
MCT-R150 - 6000/5A - CL.1 - 5VA 6000/5A
MCT-R150 drawing dimensions

■ MCT R180 Series
● Dimension
Model Width Height Thickness Inside Ø Outside Ø
MCT-R180 240 268 45 Ø180 Ø240
● Ordering Information
Model Ordering code Ratio Burden CL1.0
MCT-R180 MCT-R180 - 3000/5A - CL.1 - 5VA 3000/5A 5VA
MCT-R180 - 3200/5A - CL.1 - 5VA 3200/5A
MCT-R180 - 4000/5A - CL.1 - 5VA 4000/5A
MCT-R180 - 5000/5A - CL.1 - 5VA 5000/5A
MCT-R180 drawing dimensions