iLEC SPLIT-CORE CURRENT TRANSFORMER
SCT SERIES
1. Introduction
- The SCT Series Current Transformer is specially designed for easy installation in both new and existing electrical systems. It is primarily used for accurate current measurement at a low cost.
- Due to its relatively large phase angle error and low output power, it is not recommended for power or energy measurement applications.
- Unlike conventional current transformers, which require disconnecting the primary circuit to pass cables or busbars through the transformer core, the SCT split-core current transformer can be installed without interrupting the power supply. This significantly reduces installation time and labor costs.
2. Features
- Compact split-core design for quick and easy installation.
- Double-insulated copper winding ensures safe operation and long-term durability.
- High accuracy and reliable performance.
- Installation without interrupting the power supply.
- Reduces installation time and labor costs.
- Compact design and long service life.
3. Product code structure
4. Dimension
( Unit: mm )
| Type | W | H | D | Ø | M | N |
| SCT-16 | 39 | 46 | 20 | 16 | 24 | 38 |
| SCT-24 | 55 | 70.5 | 39 | 24 | 36 | 52 |
| SCT-36 | 66 | 81.5 | 42 | 35 | 55.5 | 35 |
| SCT-50 | 79 | 110 | 60 | 48 | 40 | 66 |
5. General Specifications
| Parameter | Values |
| Rated Frequency | 50/60Hz |
| Rated insulation voltage | 3kV AC. (1 min) |
| Rated short-time thermal current (Ith) | 60In / 1s |
| Rated dynamic current (Idyn) | 2.5Ith |
| Rated voltage (Un) | 0.66kV AV. |
| Continuous current (Id) | 1.2In |
| Operating temperature | -10ºC ~ 50ºC |
| Housing self-extinguishing class | Vo |
| Primary current | 20A ~ 1000A |
| Secondary current | 100mA, 1A, 5A |
| Current Accuracy | Cl1.0, CL0.5 |
| Phase Angle Accuracy | CL1.0, CL3.0 |
| Environment | Indoor |
6. Ordering Information
| Model | Ordering Code | Ratio (Ip/Is, A) | Burden (VA) Cl 1,0 | Internal Diameter |
|---|---|---|---|---|
| SCT-16 | SCT-16-0100-0.1 | 100/0.1A | 1.5VA | Ø16 mm |
| SCT-24 | SCT-24-0100-0.1 | 100/0.1A | 1.5VA | Ø20 mm |
| SCT-24-0030-1 | 30/1A | 1VA | ||
| SCT-24-0040-1 | 40/1A | 1.5VA | ||
| SCT-24-0050-1 | 50/1A | 1.5VA | ||
| SCT-24-0060-1 | 60/1A | 1.5VA | ||
| SCT-24-0080-1 | 80/1A | 2.0VA | ||
| SCT-24-0100-1 | 100/1A | 2.5VA | ||
| SCT-24-0050-5 | 50/5A | 1.0VA (Class 3,0) | ||
| SCT-24-0100-5 | 100/5A | 1.0VA | ||
| SCT-24-0150-5 | 150/5A | 1.0VA | ||
| SCT-24-0200-5 | 200/5A | 1.0VA | ||
| SCT-24-0250-5 | 250/5A | 1.5VA | ||
| SCT-24-0300-5 | 300/5A | 1.5VA | ||
| SCT-24-0400-5 | 400/5A | 2.0VA | ||
| SCT-24-0500-5 | 500/5A | 2.5VA | ||
| SCT-24-0600-5 | 600/5A | 2.5VA | ||
| SCT-36 | SCT-36-0100-0.1 | 100/0.1A | 1.5VA | Ø36 mm |
| SCT-36-0030-1 | 30/1A | 1.5VA | ||
| SCT-36-0040-1 | 40/1A | 1.5VA | ||
| SCT-36-0050-1 | 50/1A | 1.5VA | ||
| SCT-36-0060-1 | 60/1A | 1.5VA | ||
| SCT-36-0080-1 | 80/1A | 2VA | ||
| SCT-36-0100-1 | 100/1A | 2.5VA | ||
| SCT-36-0150-5 | 150/5A | 1VA | ||
| SCT-36-0200-5 | 200/5A | 1VA | ||
| SCT-36-0250-5 | 250/5A | 1.5VA | ||
| SCT-36-0300-5 | 300/5A | 1.5VA | ||
| SCT-36-0400-5 | 400/5A | 1.5VA | ||
| SCT-36-0500-5 | 500/5A | 2VA | ||
| SCT-36-0500-5 | 600/5A | 2.5VA | ||
| SCT-36-0800-5 | 800/5A | 3VA | ||
| SCT-50 | SCT-50-0400-5 | 400/5A | 3.75VA | Ø50 mm |
| SCT-50-0500-5 | 500/5A | 5VA | ||
| SCT-50-0600-5 | 600/5A | 5VA | ||
| SCT-50-0800-5 | 800/5A | 7.5VA | ||
| SCT-50-1000-5 | 1000/5A | 10VA | ||
| SCT-50-1200-5 | 1200/5A | 10VA | ||
| SCT-50-1500-5 | 1500/5A | 15VA | ||
| SCT-50-1600-5 | 1600/5A | 15VA |