banner-ilec

STAR DELTA RELAY

Model RT6-SD30-U

Introduction

Star Delta Relay is designed to controll three motors in the first run.

Specifications

PARAMETER VALUE
Operating voltage (Un) AC 160V–260V (A1-A2); 24V AC/DC (A1-A3)
Operating frequency 50/60Hz
Operating power < 6VA
Operating temperature -20ºC ~ 55ºC
Working (star) 0.1sec. – 30sec.
Waiting (off) 1msec. – 500msec.
Display On led, star led and delta led
Connection type Terminal connection
Weight max. 110 gr.
Contact 5A/250V AC (Resister Load)
Mounting Assembled on the DIN rail
Operating Altitude < 2000m
Cable diameter 2.5 mm²

Dimension

RT6-SD30-U Dimension

Usage of Device and Working Principle

  • Make the connections according to the diagram.
  • Max.Time (Time Steps, TS ): Adjusts the stage and display the max.time.
  • [ t ]: Divides the stage by 10 and multiply with displaying value.
    * Example: Time is 75 minutes.
  • Make stage button to 100m (100 minutes) and turn “t” button between 7-8. In this case time is adjusted to 75 minutes.
    * Note: In order to adjust much sensitive higher time values, set “t” by chronometer in low stages and in crease the stage to the time required.
    * Example: Time is 25 hours.
  • Turn stage button to 10s (10 seconds) and “t” button between 2-3. Make power on and check with a chronometer for 2.5 seconds.
  • Make the stage button 100h(100 hours). In this case, you set it more sensitive.
  • After setting the time, power on the device. Device will start timing and meanwhile led switches on-off.
    When device is timing relay contact 2 shorted to 1.
    When the timing finish (set time is up) relay led is switches on stable and contact 2 shorted to 3.
    Device keeps stable till the power is off.

Typical Connection Diagram

RT6-SD30-U Wiring Diagram

Maintenance

  • Switch off the device and release from connections.
  • Clean the trunk of device with a swab.
  • Don’t use any conductor or chemical might damage the device.
  • Make sure device works after cleaning.

Warnings

  • Please use the device according to the manual.
  • Don’t use the device in wet.
  • Include a switch and circuit breaker in the assembly.
  • Put the switch and circuit breaker nearby the device, operator can reach easily.
  • Mark the switch and circuit breaker as releasing connection for device.

External description

RT6-SD30-U External Description

Resources & Support

Review Relay iLEC RT6-SD30-U